Page tree
Skip to end of metadata
Go to start of metadata

 The Perception CORE is a software program that enable a hardware device to stream molecular image information.


Content:

Parent page:

Child pages:



Downloads

VersionRelease Date
(YYYY-MM-DD)
PlatformsDownload
2.0.55822019-10-28Win7, Win10 (x86_64)Perception Core 2.0.5582 64bit Setup.exe
2.0.55612019-10-10Ubuntu 16.04 (aarch64 L4T NVidia Jetson)PerceptionCore_2.0.5561_ubuntu16.04.tgz
2.0.55612019-10-10Ubuntu 18.04 (aarch64 L4T NVidia Jetson)PerceptionCore_2.0.5561_ubuntu18.04.tgz

See the history of updates here. Note the requirements to your PC.

 View all updates to this release
Version

Release Date

(YYYY-MM-DD)

Platforms

Download
2.0.55612019-10-10Win7, Win10 (x86_64)

Perception Core 2.0.5561 64bit Setup.exe



Dependencies 

See here a list of dependencies which might occur - dependent on your hardware configuration:


 GPU Drivers

For Perception Park software Version 2.0, please install the latest drivers from the NVidia website at https://www.nvidia.com/Download/index.aspx.

 Common Vision Blox

With version 2.0, CVB is included in Perception Park installers and does not need to be installed separately.

 Frame Grabber drivers (camera-sided)
 Silicon Software

Perception Park software supports the usage of Silicon Software framegrabbers to be used with Camera Link cameras. However, the installation of Silicon Software drivers and software has do be done correctly to get it to work. This article goes through the installation process.

Be aware that having both Silicon Software and Teledyne DALSA framegrabbers on one machine is not possible as their drivers/software will interfere with each other. Thus both components will usually be rendered non-functional until one of them is uninstalled again.

A Silicon Software framegrabber can only be used after uninstalling Teledyne DALSA software from the machine.

Before installation

It is highly recommended to unsinstall all prevoius Silicon Software products from the machine. When doing so, the uninstall process might sys that not all files could be removed. In this case you can delete the left files manually by going to "C:\Program Files\SiliconSoftware\" and "C:\ProgramData\SiliconSoftware\" and delete everything that is left inside those folders.


Download the correct installer

Perception Park software supports the Silicon Software Framegrabber "microEnable 5 marathon deepVCL". Go to it's product page (https://silicon.software/product/microenable-5-marathon-deepvcl) abd go to "Downloads". Here open up "Complete Installations" and search for "RuntimeSetup v5.5.1 (Win64) with Applets" for x64 systems or "RuntimeSetup v5.5.1 (Win32) with Applets" for x86 systems and download the installer.  Once downloaded start the installer.


Installing Silicon Software 

When running the installer you will be asked which features to install. The following images show which features are needed to be checked.

Note that the "Core Libraries" are not needed and can be skipped in case there are any problems with the camera connection.

Then click next until installation process starts ad wait until it has finished.


Activating Applets

After installation, the Silicon Software applet "Acq_DualBaseAreaGray" has to be enabled for the framegrabber, otherwise it will not work. To do this, open up Silicon Software's microDisplay and go to File→Load Applet

Note that to activate the applet, the applet needs to be selected from the list, then hit the button in the bottom center (it should display a color schematics of the grabber if the applet is not yet installed)



Verify installation

Now, if you go to the installed software in your Windows control panel, it should list the following items. 



Now the device is ready to be used.

 Teledyn Dalsa Xtium CL-MX4
Download an installer from below and follow the instructions of the installation guide.


Supported
Frame Grabbers
Download

Teledyn Dalsa Xtium CL-MX4

140518-Xtium-CL_MX4_1.20.01.0229.zip

Sapera LTsapera_lt_831_camexpertsetup.exe

Description

The Perception CORE is a software program that enable a hardware device to stream molecular image information.

A hardware device based on the Perception CORE technology is named Perception System. It abstracts and standardizes an interfaced HS camera, allows to apply Chemical Color Imaging and to streams extracted features (e.g. color information) to a machine vision solution. A Perception System gets configured by means of the Perception Studio program. The client application can set a configuration available to be active on the Perception System and therefore can influence what information has to be extracted from the HS camera data.

The Perception CORE program is capable to run on GPU-based devices.

Be sure the Perception CORE software is of same version than your Perception Studio program!

Content

  • Camera interface:
    • GigE Vision cameras
    • CameraLink cameras
      • Specim FX10, FX17
      • Allied Vision Goldeye CL033
  • Output interface
    • GigE Vision
    • CameraLink

Not connected cameras will result in a warning in the log window of the program during startup.
If no camera is connected, the program will terminate.
In case you like to configure your Perception System to be runnable only with one specific camera model (like GigE Vision), please make sure to install exclusively the needed interface plugin (like GigE Vision cameras). Otherwise the startup of the Perception System will be slowed down.

Usage

A Perception System based on Perception CORE technology is used as processing engine (as an adapter) in between a HS camera and the customers Machine Vision solution. It enables streaming of molecur information.

License Activation

Obtain an USB dongle from your distributor.

Manuals

Good to Know

  • Please ensure to use a Perception CORE based device always together with a Perception Studio of same version. So, Perception Studio Inline 1.7.3576 is compatible to Perception CORE 1.7.3576.
  • Find out your local sales distributive on Hyperspectral hardware and software from here.

 


 © 2019 by Perception Park GmbH
The content of this page and any attached files are confidential and intended solely for the addressee(s). Any publication, transmission or other use of the information by a person or entity other than the intended addressee is prohibited. If you receive this in error please contact Perception Park and delete copied material. Perception Park GmbH, Wartingergasse 42, A-8010 Graz; Austria; FN 400381x

  • No labels